Showing results: 91 - 105 of 403 items found.
-
MC-1000 -
Martel Calibrators
The MC-1000 Process Calibrator provides high accuracy calibration, common DMM functions including read and source thermocouples, RTDs, Ohms, current, pressure, frequency and test continuity. This single calibration instrument will calibrate virtually any process device including: read and source thermocouples, RTDs, Ohms, Voltage, Current, Frequency, Pressure, and test continuity.
-
DT4 -
North Atlantic Industries
The DT4 module (the enhanced version) features 24 programmable channels for either input (voltage or contact sensing with programmable, on-module pull-up/pull down current sources), or output (current source, sink, or push-pull) up to 500 mA per channel from an applied, external 3 – 60 VCC source. These modules can sense broken input connections and whether an input is shorted to +VCC or to ground. Additional features of the DT4 (Enhanced Version) are listed below.
-
Radio Ampstik® 2023 -
SensorLink
The Radio Ampstik uses the same current sensor technology as the original SensorLink Ampstik. It quickly takes accurate current measurements and direction of current flow indication. Knowing source and load direction is essential for power system protection, load balancing, and metering.
-
A.H.Systems, Inc.
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current.
-
Playing With Fusion Inc
A power supply is an electrical device that supplies electric power to an electrical load. The main purpose of a power supply is to convert electric current from a source to the correct voltage, current, and frequency to power the load.
-
ResTest -
Jandel Engineering Limited
The new Jandel ResTest Test Unit is a constant current source and digital voltmeter with large colour screen, supplying constant currents between 1uA and 10mA, and measuring voltages from 0.04mV to 4000mV.
-
Toellner Electronic Instrumente GmbH
A power supply is an electrical device that supplies electric power to an electrical load. The main purpose of a power supply is to convert electric current from a source to the correct voltage, current, and frequency to power the load.
-
UHPS -
RARA Electronics Corporation
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
Pulse Electronics
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
PDX-1/7 -
Langeo Co., Ltd.
PDX-1 and PDX-7 DC rechargeable power source is available for resistivity/IP survey, light and portable with high voltage and large current.
-
779647-31 -
NI
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
ProDAQ 5821 -
Bustec Ltd.
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
CS-8000 Series -
IWATSU Electronic Co., Ltd.
The CS-8000 series are equipped with a high-voltage source of up to 5 kV and a high-current source of 2 kA. It features Pulse output, Gate pattern, and very small current measurement capabilities, and it supports the design evaluation of wideband-gap semiconductors such as SiC and GaN.
-
VX Instruments GmbH
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measuring units (VMU, CMU).High-voltage SMUs work as a regulated voltage source and are able to generate very high output voltages.
-
SIM922A -
Stanford Research Systems, Inc.
The SIM922A has a programmable, precision 10 µA current source to provide sensor excitation. Results can be displayed in either kelvins or volts.